홈 • Clinical Solutions • Case Studies • Optimizing Process Workflow Through Layout Redesign RELATED PRODUCTS HistoCore PELORIS 3 Premium Tissue Processing System HistoCore AUTOCUT - Automated Rotary Microtome BOND-III Fully Automated IHC and ISH Staining System HistoCore Arcadia H - Heated Paraffin Embedding Station Optimizing Process Workflow Through Layout Redesign The Leica Biosystems Content and Evidence team has partnered with a private, non-profit, integrated health system to optimize their new laboratory layout to ensure efficient process flow. The laboratory is most interested in ensuring their new laboratory space is structured to best handle the initial volume while allowing for increased growth over the coming years. The new histology laboratory will include routine, special, and immunohistochemistry staining. The Leica Biosystems Content and Evidence team was provided an initial architect drawing with planned equipment placement. The team conducted interviews with lab directors, and staff to obtain all necessary input on process requirements. The Leica Biosystems Content and Evidence team mapped the process flow and redesigned the layout to rearrange the placement of process steps and equipment. Below is the initial layout provided to the team and the recommended layout after adjustments. Image 그림 1. 고객의 초기 설계 도면에 나타난 프로세스 흐름 Image 그림 2. 권장 검사실 레이아웃에 따른 프로세스 흐름 The new laboratory space included space for: Separate room for 4 tissue processors and waste storage 3 Embedding stations with room for 6 total stations 8 Microtomy stations with room for 12 total stations Dedicated island for routine staining Dedicated island for special staining including hood for hand stains Large area for Immunohistochemistry preparations and staining Large workspace for Case Assembly and distribution of slides Wall space for storage of blocks and slides Image The estimated travel distance for the specimen of the initial drawing was 143.2 feet and included two crossover process steps. The recommended layout eliminated all crossover process steps and had an estimated travel distance for the specimen of only 79.9 feet. That is a 44.2% reduction in wasted travel distance. The Leica Biosystems Content and Evidence team was able to visually demonstrate the improvements using a spaghetti mapping process which resulted in the necessary gains. Projections and Realized Results are specific to the institution where they were obtained and may not reflect the results achievable at other institutions. Leica Biosystems 콘텐츠는 Leica Biosystems 웹사이트 이용 약관의 적용을 받으며, 이용 약관은 다음에서 확인할 수 있습니다. 법적고지. 라이카 바이오시스템즈 웨비나, 교육 프레젠테이션 및 관련 자료는 특별 주제 관련 일반 정보를 제공하지만 의료, 규정 또는 법률 상담으로 제공되지 않으며 해석되어서는 안 됩니다. 관점과 의견은 발표자/저자의 개인 관점과 의견이며 라이카 바이오시스템즈, 그 직원 또는 대행사의 관점이나 의견을 나타내거나 반영하지 않습니다. 제3자 자원 또는 콘텐츠에 대한 액세스를 제공하는 콘텐츠에 포함된 모든 링크는 오직 편의를 위해 제공됩니다. 모든 제품 사용에 다양한 제품 및 장치의 제품 정보 가이드, 부속 문서 및 작동 설명서를 참조해야 합니다. Copyright © 2024 Leica Biosystems division of Leica Microsystems, Inc. and its Leica Biosystems affiliates. All rights reserved. LEICA and the Leica Logo are registered trademarks of Leica Microsystems IR GmbH. Contact Our Clinical Expert Now If you have viewed this educational webinar or training and would like to apply for continuing education credits with your certifying organization, please download the form to assist you in adding self-reported educational credits to your transcript. 자가보고식 교육학점을 신청 하세요 SHARE Facebook Twitter LinkedIn Email