홈 • Knowledge Pathway • 에디토리얼 • An Innovative Methodology to Measure Product Usability Histotechnicians are at the Center of our Focus An Innovative Methodology to Measure Product Usability Histotechnicians are at the Center of our Focus Lance Mikus MBA Whether it’s a new imaging device or a software product, at Leica Biosystems we want to make our products so simple to use that they naturally fit into the Histotechnician’s daily life in a Pathology lab. To do this, we follow a testing process to measure product usability during product development and design of a new product. We refer to this testing methodology as User Experience (UE). Although we study multiple users, including Pathologists, IT professionals and Lab Directors, in this article we will discuss how we measure usability specifically with Histotechnicians using, among other techniques, an innovative approach called the System Usability Scale (SUS).1 Image What Usability Metrics do we Measure? When measuring the User Experience of a product during the design phase, we visit Pathology labs around the world and test prototypes with many Histotechnicians. We prepare testing scenarios that the Histotechnician will experience in their day-to-day work life. During learning cycles we test, measure and record the following: System Usability Scale (SUS) for each Histotechnician after each testing session. Task completion rate and time to complete typical tasks for which the product will be used Ease of use score per the Histotechnician feedback after performing each task Direct verbal feedback from Histotechnicians after testing the product What is the System Usability Scale (SUS)? SUS is a ten-item likert scale that is designed to assess overall opinions of a product (or technology) in development by answering 10 survey questions regarding a product tester’s opinion of product usability, complexity, support needed, integration ability, and confidence using the product. SUS results are expressed as percentages with low scores being in the 55-69, average scores being 70-85, an above average scores being 85-100. Design, Test with User, Iterate, Repeat Process Once we have measured the usability during a learning session in a Pathology lab, we take those scores and all the rich learnings back to our Pathology Imaging headquarters and study the results in an Obeya Room (Obeya means “large room” or “war room”). In this room, we carefully study the rich user data as a team, including engineers, software developers, marketers, and product managers. We then identify which changes are needed to the product before going out for the next learning and testing session with the Histotechnician. The changes to the product are made and then we repeat the testing and measuring process. See below for some UX DNA data for which we collected during a recent product development program. Image Figure 1 (above): As part of UX DNA testing during product development, we measure the time it takes Histotechnicians to complete common tasks for which the product in development is intended to be used. Blue, red and green bars show task time for different iterations over time. Purple bar shows the goal (or reference point). As shown above, task times generally improve dramatically after each iteration as learnings are applied from each previous session to the next design iteration. System Usability Score (%) Design Iteration Actual Goal Iteration #1 73% 85% Iteration #2 73% 85% Iteration #3 91% 85% Iteration #4 89% 85% Iteration #5 94% 85% Table 1 (above): System Usability Scales (SUS) measurements after product testing sessions over several iterations. SUS are designed to assess overall opinions of a product (or technology) in development by answering 10 survey questions regarding a product tester’s opinion of product usability, complexity, support needed, integration ability, and confidence using the product. Results are expressed as a percent; with 40% being a poor grade and >85% being an excellent grade (as the table indicates, SUS increased from 73% to 94% over 5 product design iterations indicating excellent scores by iteration #5.) SUS results are expressed as percentages with low scores being in the 55-69, average scores being 70-85, an above average scores being 85-100. A High Quality Product Experience for Our Customers In order to release a product to our valued customers, Leica Biosystems is committed to achieving high scores in User Experience testing before the product’s design is completed. Often times, this may require many rounds of user testing and associated design changes before a product is ready to launch. This rigorous process is very important for our customers as it helps ensure that when a new product is introduced into the Pathology Lab it will be easy to operate and provide high value to the customer. For more short innovation articles like this, please go to LeicaBiosystems.com/Knowledge Pathway. Coming Soon! Look for our next article on Leica Biosystems innovations! 발표자 소개 Lance Mikus , MBA Lance Mikus earned his bachelor’s degree from UCLA. He worked as a scientist and lab manager at the UW-Madison Medical School, resulting in several publications, and went on to earn an MBA focused on Entrepreneurship and Marketing from the UW-Madison School of Business. Mr. Mikus has 20 years of commercial operations experience in the healthcare industry. He also holds a green belt in six sigma quality practices, is a certified practitioner in launch excellence and has been awarded 5 patents. 참조 문헌 1. Brooke, J. (1986). "SUS: a "quick and dirty" usability scale". In P. W. Jordan, B. Thomas, B. A. Weerdmeester, & A. L. McClelland (eds.). Usability Evaluation in Industry. London: Taylor and Francis. 라이카 바이오시스템즈 Knowledge Pathway 콘텐츠는 에서 이용할 수 있는 라이카 바이오시스템즈 웹사이트 이용 약관의 적용을 받습니다. 법적고지. 라이카 바이오시스템즈 웨비나, 교육 프레젠테이션 및 관련 자료는 특별 주제 관련 일반 정보를 제공하지만 의료, 규정 또는 법률 상담으로 제공되지 않으며 해석되어서는 안 됩니다. 관점과 의견은 발표자/저자의 개인 관점과 의견이며 라이카 바이오시스템즈, 그 직원 또는 대행사의 관점이나 의견을 나타내거나 반영하지 않습니다. 제3자 자원 또는 콘텐츠에 대한 액세스를 제공하는 콘텐츠에 포함된 모든 링크는 오직 편의를 위해 제공됩니다. 모든 제품 사용에 다양한 제품 및 장치의 제품 정보 가이드, 부속 문서 및 작동 설명서를 참조해야 합니다. Copyright © 2024 Leica Biosystems division of Leica Microsystems, Inc. and its Leica Biosystems affiliates. All rights reserved. LEICA and the Leica Logo are registered trademarks of Leica Microsystems IR GmbH. Knowledge Pathway의 이 교육용 웨비나, 학습 자료 또는 자습서를 보고 인증 기관에 교육 크레딧을 신청하려면 다음 양식을 다운로드하십시오. 획득한 교육 크레딧을 개인 성적표에 직접 기입할 수 있습니다. (단, 대한민국은 적용 대상 아님) 자가보고식 교육학점을 신청 하세요 최신 Knowledge Pathway를 이메일로 직접 받아볼 수 있습니다. 지금 구독하세요! 더 많은 훌륭한 집필진을 기다리고 있습니다. 원고를 보내주시면 담당자가 연락드리겠습니다. Send your writing! SHARE Facebook Twitter LinkedIn Email