Image HistoCore SPECTRA Workstation – stain and coverslip slides more quickly with consistent diagnostic confidence. Image HistoCore SPECTRA Stainer and Coverslipper with top covers open Image Experience uncompromised flexibility and reduced turnaround time with the complete workstation. Image Color-coded rack technology provides visual distinction and used to automatically start protocols. Image The color-coded racks are inserted and individual protocols automatically start. Each protocol is matched to a specific color. Image The coverslipper opens up to provide easy access to ready-to-use HistoCore SPECTRA CV coverslips and mounting media. Image HistoCore SPECTRA H&E stains provide proven consistent diagnostic stain quality up to 1,600 slides. X HistoCore SPECTRA Workstation Workstation Kit - 14051254355, ST - 14051254354, CV - 14051454200 Faster Workflows and Proven Consistency from Slides 1 to 1,600 Your time matters. Speed up slide processing while maintaining quality and consistency with the HistoCore SPECTRA Workstation, the only workstation that provides consistent staining from slides 1 to 1,600. It also offers the fastest glass coverslipping drying time on the market at only 5 minutes, processing slides that are instantly dry to the touch. Work harder. Process up to 570 dried slides per hour so you can transport immediately and not delay diagnosis. Improve efficiency by 20%. This solution provides the unique flexibility to process H&E and special stains simultaneously at high throughput in parallel with 52 stations. Save time. By using specifically-designed consumables, users ensure consistent staining quality and reduce the number of manual corrective actions for coverslipped slides. Contact us to get a quote. Call 00 308 321 0320 to speak with a representative. For in vitro diagnostic use. Stainer Coverslipper Consumables Specifications Downloads Resources Configurations HistoCore SPECTRA ST Stainer Features Routine & Special Staining with Dual Robotic Arms Dual robotic arms and multiple reagent stations ensure each rack is stained efficiently. Users can process up to 330 slides per hour without compromising flexibility or lowering the turnaround time. In addition, the innovative design and 52 cuvette stations enable H&E and special stains to run simultaneously at a high throughput. View Interactive 3D Model Image No External Oven Needed For better specimen adherence to the glass slide, baking/drying is integrated into the staining process on the HistoCore SPECTRA ST with a built-in hot air oven that eliminates excess paraffin. No external oven or additional user interaction is required, and the oven can process up to six racks at the same time. That means faster turnaround times and quicker processing. Image Precise Reagent Management and Cost Control with Unique Single Slide Counting Have precise control over reagent conditions, and coordinate reagent exchange using RFID-monitored consumables, color-coded rack technology, and a unique slide counter. Together, these features minimize user errors, save time, control costs, and reduce waste in the lab. Image Intuitive User Interface Minimizes Hands-On Time The easy-to-use software of the HistoCore SPECTRA ST automatically calculates optimal bath layouts, eliminating manual steps. As a result, no hands-on interaction is needed, which helps improve lab efficiency. Image Reduced Errors with Protocol Autostart The patented color-coded rack technology provides a clear visual distinction and automatically starts individual protocols when the racks are inserted. This reduces human error by making it easy to recognize and correctly allocate the racks and slides to their designated staining protocols. Oversight and Control through Traceability HistoCore SPECTRA H&E Staining System provide the clarity and consistency you expect. In addition, RFID technology enables you to accurately track reagent usage, slide volume, and maintain records. HistoCore SPECTRA CV Coverslipper Features Market-Leading Throughput and Drying Time The first and only solution in the market with dual glass coverslip lines enabling the highest throughput: up to 570 dried slides per hour. With an integrated hot air drying oven, it achieves a drying time of only 5 minutes, providing the fastest turnaround time for your lab. Image Boost Coverslipping Throughput and Efficiency The dual and independent coverslip lines don’t just deliver the highest throughput, they also give users the flexibility to manually load slides in a continuous workflow. In addition, the coverslipper features an enhanced lay down mechanism, a smooth handling process (push method for coverslipping readiness), and validated ready-to-use consumables with RFID technology. These consumables include the HistoCore SPECTRA CV X1 rapid drying, xylene-based mounting media. An antioxidant is added to inhibit stain fading and prevent the formation of annual rings. It sets up quickly, allowing slide preparations to be handled immediately after mounting. Image Large Workload Capacity The 9-rack output drawer can handle a total capacity of 270 slides. That allows users to focus on the many other important tasks throughout the lab. Image Never Worry about Broken Glass The unique glass detection sensor automatically removes and transfers broken coverslips to better protect the safety of the user while handling slides and to help maintain the integrity of tissue specimens. Capability to Handle Multiple Labels The new coverslipping process supports smooth handling of different slide labels, providing flexibility you demand. Consumables Achieve Consistent Quality from Slide 1 to 1,600 Rest easy knowing the slides processed are of consistently high quality. Leica Biosystems’ validated protocols and the HistoCore SPECTRA H&E Staining System eliminate day-to-day variation. Better yet, these H&E stains provide the clarity and definition to help speed diagnostic efficiency for pathologists and patients. Image Ready-to-Use Coverglass and Mounting Media HistoCore SPECTRA CV X1 is a rapid drying, xylene based mounting media. An antioxidant is added to inhibit stain fading and prevent the formation of annual rings. It sets up quickly, allowing slide preparations to be handled immediately after mounting. SPECTRA X1 is soluble in xylene, toluene, and most xylene substitutes. HistoCore SPECTRA CV Coverglass allows for maximum reduction of fingerprints due to ready-to-use coverglass cartridges. Enhanced packaging reduces broken coverglass and humidity. Image Product Specifications HISTOCORE SPECTRA ST STAINER Instrument Dimensions, Hood Closed (W x D x H): 135.4 x 78.5 x 58.5 cm (53.3 x 30.9 x 23.1 in) Instrument Dimensions, Hood Open (W x D x H): 135.4 x 78.5 x 94.3 cm (53.3 x 30.9 x 37.1 in) Weight (Empty w/o Reagents and Accessories): 185 kg (407 lbs) Net Weight (with Reagents): Approx. 220 kg (485 lbs) Certifications: CE , c-CSA-us Nominal Supply Voltages: 100 to 240V Throughput: Up to 330 H&E Slides per Hour Capacity of Slide Rack: 30 (5 Slide Rack for Special Stains) Reagent Cuvette Stations: 36 Cuvette Volume: 380 mL Water Flow Cuvette Stations: 6 Stations in Input and Output Drawer: 5 Each, Continuous Loading Possible with Max. 150 Slides Drying Oven Stations: 6 HISTOCORE SPECTRA CV COVERSLIPPER Instrument Dimensions, Hood Closed (W x D x H): 69 x 78.5 x 58.5 cm (27.2x 30.9 x 23.1 in) Instrument Dimensions, Hood Open (W x D x H): 69 x 78.5 x 94.3 cm (27.2 x 30.9 x 37.1 in) Weight (Empty w/o Reagents and Accessories): 110 kg (242 lbs) Nominal Supply Voltages: 100 to 240 V AC +10% Throughput: Up to 570 slides per hour Usable Specimen Slides: In Accordance with DIN ISO 8037/1 (76 mm x 26 mm) Coverslip Quantity: 300 Coverslips per Magazine Coverslip Size: 24 mm x 50 mm Mounting Media: HistoCore SPECTRA CV X1, Xylene based Specimen Slide Holders: 30 Specimen Slides HISTOCORE SPECTRA H&E STAINING SYSTEMS Staining Intensity: S1 (Light to Moderate) S2 (Moderate to Dark) Capacity: 1,600 Slides On-stainer Expiration 7 days Staining component Volume: 380 mL/bottle Staining System Components: SPECTRA Hemalast SPECTRA Hematoxylin SPECTRA Differentiator SPECTRA Bluing SPECTRA Eosin HISTOCORE SPECTRA CV CONSUMABLES HistoCore SPECTRA CV Coverglass: 1 Case = 8 cartridges with 300 coverslips per cartridge HistoCore SPECTRA CV X1 Mounting Media: 1 Case = 2 bottles with 150ml each Downloads Brochure Brochure - HistoCore SPECTRA Workstation - EN (18485 Rev B) Size: 1.8 MB, Type: pdf Brochure - HistoCore SPECTRA Workstation - DE (18914 Rev B) Size: 1.47 MB, Type: pdf Brochure - HistoCore SPECTRA Workstation - FR (18915 Rev B) Size: 1.47 MB, Type: pdf Brochure - HistoCore SPECTRA Workstation - ES (18916 Rev B) Size: 1.47 MB, Type: pdf Brochure - HistoCore SPECTRA Workstation - IT (18917 Rev B) Size: 1.47 MB, Type: pdf Brochure - HistoCore SPECTRA Workstation - PT (18918 Rev B) Size: 1.47 MB, Type: pdf Brochure - HistoCore SPECTRA Workstation - KO (18919 Rev B) Size: 938.24 KB, Type: pdf Brochure - HistoCore SPECTRA Workstation - ZH (18920 Rev B) Size: 1.33 MB, Type: pdf Brochure - HistoCore SPECTRA Workstation - JP (18921 Rev B) Size: 621.63 KB, Type: pdf Certificate DoC HistoCore SPECTRA CV D Size: 429.58 KB, Type: pdf DoC HistoCore SPECTRA ST D Size: 429.23 KB, Type: pdf SDS SPECTRA CV X1 DE Size: 154.96 KB, Type: pdf SPECTRA CV X1 EN Size: 154.74 KB, Type: pdf Testimonial Testimonial - HistoCore SPECTRA CV Coverslipper Reduces Drying Completion Time - EN (200523 Rev A) Size: 258.46 KB, Type: pdf 200523 Rev A Wisconsin Diagnostic Laboratories Improves Stain Quality and Workflow Size: 1008.81 KB, Type: pdf Testimonial - Inform Diagnostics Teams Up With LBS To Achieve Class Leading Accuracy and Efficiency - EN (200656 Rev A) Size: 957.1 KB, Type: pdf IFU HistoCore RFID-Registration SPECTRA ST 2v0M Multi Size: 1.25 MB, Type: pdf HistoCore RFID Registration SPECTRA CV 1v7J Multi Size: 1.28 MB, Type: pdf HistoCore SPECTRA CV IFU 2v5P cs Size: 8.83 MB, Type: pdf HistoCore SPECTRA CV IFU 2v5P da Size: 8.85 MB, Type: pdf HistoCore SPECTRA CV IFU 2v5P de Size: 8.95 MB, Type: pdf HistoCore SPECTRA CV IFU 2v5P en Size: 8.82 MB, Type: pdf HistoCore SPECTRA CV IFU 2v5P es Size: 8.95 MB, Type: pdf HistoCore SPECTRA CV IFU 2v5P fi Size: 8.88 MB, Type: pdf HistoCore SPECTRA CV IFU 2v5P fr Size: 9 MB, Type: pdf HistoCore SPECTRA CV IFU 2v5P hr Size: 9.02 MB, Type: pdf HistoCore SPECTRA CV IFU 2v5P hu Size: 9 MB, Type: pdf HistoCore SPECTRA CV IFU 2v5P it Size: 8.9 MB, Type: pdf HistoCore SPECTRA CV IFU 2v5P ja Size: 9.27 MB, Type: pdf HistoCore SPECTRA CV IFU 2v5P ko Size: 9.24 MB, Type: pdf HistoCore SPECTRA CV IFU 2v5P nl Size: 8.8 MB, Type: pdf HistoCore SPECTRA CV IFU 2v5P no Size: 8.76 MB, Type: pdf HistoCore SPECTRA CV IFU 2v5P pl Size: 9.01 MB, Type: pdf HistoCore SPECTRA CV IFU 2v5P pt Size: 8.88 MB, Type: pdf HistoCore SPECTRA CV IFU 2v5P ro Size: 8.87 MB, Type: pdf HistoCore SPECTRA CV IFU 2v5P ru Size: 9.14 MB, Type: pdf HistoCore SPECTRA CV IFU 2v5P sk Size: 8.93 MB, Type: pdf HistoCore SPECTRA CV IFU 2v5P sr Size: 8.93 MB, Type: pdf HistoCore SPECTRA CV IFU 2v5P sv Size: 8.81 MB, Type: pdf HistoCore SPECTRA CV IFU 2v5P tr Size: 8.78 MB, Type: pdf HistoCore SPECTRA CV IFU 2v5P zh Size: 9.13 MB, Type: pdf HistoCore SPECTRA CV IFU 2v5P lt Size: 8.85 MB, Type: pdf HistoCore SPECTRA CV IFU 2v5P kk Size: 8.97 MB, Type: pdf HistoCore SPECTRA ST IFU 2v4Z da Size: 9.22 MB, Type: pdf HistoCore SPECTRA ST IFU 2v4Z de Size: 9.67 MB, Type: pdf HistoCore SPECTRA ST IFU 2v4Z cs Size: 9.18 MB, Type: pdf HistoCore SPECTRA ST IFU 2v4Z en Size: 9.15 MB, Type: pdf HistoCore SPECTRA ST IFU 2v4Z es Size: 9.54 MB, Type: pdf HistoCore SPECTRA ST IFU 2v4Z fi Size: 9.32 MB, Type: pdf HistoCore SPECTRA ST IFU 2v4Z fr Size: 9.62 MB, Type: pdf HistoCore SPECTRA ST IFU 2v4Z hr Size: 9.55 MB, Type: pdf HistoCore SPECTRA ST IFU 2v4Z hu Size: 9.56 MB, Type: pdf HistoCore SPECTRA ST IFU 2v4Z kk Size: 9.27 MB, Type: pdf HistoCore SPECTRA ST IFU 2v4Z lt Size: 9.19 MB, Type: pdf HistoCore SPECTRA ST IFU 2v4Z ja Size: 9.72 MB, Type: pdf HistoCore SPECTRA ST IFU 2v4Z ko Size: 9.6 MB, Type: pdf HistoCore SPECTRA ST IFU 2v4Z nl Size: 9.39 MB, Type: pdf HistoCore SPECTRA ST IFU 2v4Z no Size: 9.36 MB, Type: pdf HistoCore SPECTRA ST IFU 2v4Z pl Size: 9.44 MB, Type: pdf HistoCore SPECTRA ST IFU 2v4Z pt Size: 9.57 MB, Type: pdf HistoCore SPECTRA ST IFU 2v4Z ro Size: 9.43 MB, Type: pdf HistoCore SPECTRA ST IFU 2v4Z ru Size: 9.57 MB, Type: pdf HistoCore SPECTRA ST IFU 2v4Z sk Size: 9.47 MB, Type: pdf HistoCore SPECTRA ST IFU 2v4Z sr Size: 9.42 MB, Type: pdf HistoCore SPECTRA ST IFU 2v4Z sv Size: 9.35 MB, Type: pdf HistoCore SPECTRA ST IFU 2v4Z tr Size: 9.4 MB, Type: pdf HistoCore SPECTRA ST IFU 2v4Z zh Size: 9.47 MB, Type: pdf HistoCore SPECTRA ST IFU 2v4Z it Size: 9.51 MB, Type: pdf Resources Videos and 3D Interactive Models X HistoCore SPECTRA Workstation Workflow Video (English) Customer Testimonials Image HistoCore Spectra CV Coverslipper reduces turnaround time by 47% from glass coverslipping to slide drying process completion. An independent university pathology hospital compared the HistoCore SPECTRA CV Coverslipper with the Sakura Tissue Tek® Film Coverslipper. Result: The use of the built-in oven reduced the drying process time by 47% compared to using the drying station of their existing film coverslipper. Read more Image "The fact that the HistoCore SPECTRA ST stainer and stains maintains the same quality from the first slide to the sixteen-hundred is amazing to me.” Wisconsin Diagnostic Laboratories Histology Department in Milwaukee, Wisconsin, handles more than 24,000 cases and 500,000 blocks every year. They needed to update their staining equipment after 20 years of service and looked for a replacement that would continue their long tradition of highly accurate, efficient service. Read more Image “The nuclear detail is of excellent quality, much like looking at a picture in a book. The pathologists just love the quality of the slides.” Always looking to improve its quality and streamline operational efforts, Inform Diagnostics teamed up with Leica Biosystems to assess whether the HistoCore SPECTRA systems provided a cost-effective update to Inform Diagnostics’ staining technology that would meet or exceed its industry-leading quality standards. Read more Configurations Workstation Solution HistoCore SPECTRA ST Stainer (14051254354) HistoCore SPECTRA CV Coverslipper (14051454200) HistoCore SPECTRA CV Cover Glass (3800152) and Mounting Media (3801733) HistoCore SPECTRA Workstation Kit / Transfer Unit (14051254355) Stainer Only HistoCore SPECTRA ST Stainer (14051254354) Coverslipper Only HistoCore SPECTRA CV Coverslipper (14051454200) HistoCore SPECTRA CV Cover Glass (3800152) and Mounting Media (3801733) Education Webinars (Knowledge Pathway)The H&E Stain – A Lesson on Consistency and Reproducibility Tutorials (Knowledge Pathway)Special Stain Techniques for the Evaluation of Mucins Tutorials (Knowledge Pathway)H&E Staining Overview: A Guide to Best Practices Tutorials (Knowledge Pathway)An Introduction to Routine and Special Staining Related Products BOND-III Fully Automated IHC and ISH Staining SystemLEARN MORE